Bioquell ProteQ Modular VHP System

Bioquell ProteQ

Treat nearly any room or area in your facility with this mobile, scalable system. Ecolab’s Bioquell ProteQ features wireless communication technology, built-in aeration, and the option to add additional aeration capability.

Benefits of Bioquell ProteQ

Bioquell ProteQ is a great choice for everything from small labs to large bioprocessing areas, for routine application to emergency remediation.

Powerful hydrogen peroxide vapor distribution reduces cycle times, and wireless functionality can network multiple units.

Use Bioquell ProteQ for:

  • Biopharmaceutical manufacturing areas
  • GMP/GLP laboratories
  • Biosafety labs 
  • Animal facilities
  • Production areas such as RABS that are hard to clean manually
  • Cleanrooms and anterooms


Why Choose Bioquell ProteQ

Icon displaying Customized

Effective

Hydrogen peroxide vapor achieves a 6-log reduction within an enclosed area.

Puzzle icon

Integrated

One piece of equipment performs both vaporization and aeration. If needed, you can store additional aeration units within the unit. Use in existing facilities without complex modifications.

Icon of finger pushing a button - easy to use

Easy to Use

Wireless connectivity allows for rapid setup and reduced downtime. Able to store and run 1000s of predefined cycles.

Icon of a clipboard - Compliant

Compliant

Thermal and PDF printouts of key cycle data; 21 CFR Part 11-compliant audit trail available.

Bioquell ProteQ Components and Setup

Ecolab Bioquell ProteQ Components

Components:

  1. The main structure of the system contains:
    • The hydrogen peroxide vapor distribution system for rooms up to 400 m³ (depending on configuration, load and environmental conditions).
    • Dual-bottle module with RFID reading for proper loading, large volume treatment and key data collection.
    • Built-in aeration, which is a standard feature in every Bioquell ProteQ unit.
  2. The wireless control module combines a thermal printer and a color touch screen with graphic interface.
  3. Additional aeration units are stored in the main structure of the system.
Illustration of ProteQ room configuration

Multiple-System Setup

You can run up to three Bioquell ProteQ systems simultaneously from a single master controller, making larger spaces simple to treat. For zones requiring more than three systems, multiple master controllers can be used. Contact us for details.


Related Products and Accessories

Low Level Peroxide Sensor XAM-5100

Bioquell HPV-AQ

This 35% aqueous hydrogen peroxide solution is what the Bioquell L-4 uses to produce hydrogen peroxide vapor.

Bioquell Indicators

Bioquell Biological Indicators (BIs)

Our biological indicators are made from Geobacillus stearothermophilus endospores to help you validate a Bioquell cycle.

Bioquell_Room_CI.jpg

Bioquell Room Chemical Indicators (CIs)

Confirm that a Bioquell cycle has achieved the expected vapor distribution and exposure performance with these easy-to-read chemical indicators. A chemical strip reacts to a Bioquell cycle and changes color to correlate with the cycle’s expected performance. For use in rooms and enclosed areas 10m3 and larger.

Additional Aeration Units

Additional Aeration Units

More aeration units can be added to the Bioquell ProteQ to disperse vapor and provide further aeration, resulting in faster cycles. These units connect wirelessly with the system. Up to two aeration units can be stored within the frame of the Bioquell ProteQ, for ease of transport.

Bioquell_Low_Level_Peroxide_Sensor_XAM_5100.jpg

Low-Level Peroxide Sensor (XAM-5100)

This sensor helps you evaluate the levels of hydrogen peroxide remaining after completion of a cycle. It provides an added level of reassurance beyond the readings given by the Bioquell ProteQ system.

Bioquell Validation

Validation for Bioquell Services

To meet regulatory requirements, you may need to deliver proof that your solution performs as it should. Ecolab provides trained engineers and the validation documentation you need to comply with regulations.

Doctor working on a sensitive equipment in a cleanroom

Use Even on Sensitive Electronics and Equipment

Our hydrogen peroxide vapor is tough on bioburdens, but gentle on electronics and equipment. Unlike spray-and-wipe methods, there are no additional steps to remove residue. When you need to reduce the risk of bio-contamination in spaces that contain hard-to-clean equipment, Bioquell is ideal. Before using Bioquell on your electronic equipment, check with the manufacturers to confirm compatibility.


FAQs About Bioquell ProteQ

Can the Bioquell ProteQ control my HVAC?
Yes. The system can communicate with your BMS via volt-free contacts to indicate cycle progress. The BMS can then control your HVAC accordingly.

What if the wireless connection stops working in my building?
While extremely rare, if this situation occurs, we can supply a wireless range extender to ensure you're able to run cycles without interruption.

Contact Us

Are you interested in the Bioquell ProteQ to help in your facility? Use this form to request a quote, and we’ll be in touch soon.

Contact Ecolab Life Sciences

Ecolab Life Sciences is a trusted partner for quality, safety and efficiency in biopharmaceutical manufacturing. Contact us to learn how we can help you achieve your goals and keep you on the cutting edge.

* indicates required field

By checking "Yes", you are agreeing that Ecolab may contact you via email with promotional offers, updates, and other information. If you wish to continue your customer relationship without receiving marketing communication, you may submit your information without checking this box.

Data Privacy Concerns? See our Privacy Policy.